EMERGENCY ROPE PULL SWITCH LEFT SIDE 2NC

XY2CJL17https://download.schneider-electric.com/files?p_Doc_Ref=PF123233&p_File_Type=rendition_4000_pnge-stop rope pull switch XY2CJ - left side - 2NC - Pg13.5.Label:Preventa XY2C-range of product:Preventa XY2-product or component type:latching emergency stop rope pull switch-device short name:XY2C-Range Presentation:Robust metal enclosure for use in severe environments Emergency stops rope pull switches conforming to EN/ISO 13850, EN/IEC 60947-5-5
XY2CH (up to 15 metre trip wire)
- Reversible for trip wire anchoring point on the left or right - Degree of protection IP65. - 1 NC + 1 NO or 2 NC contacts - Reset by pushbutton, mushroom head pushbutton with or without key release, pull knob. - Visual indication of contact status and trip wire tension. - Approvals: CE and UL/CSA XY2CE (up to 50 metre trip wire)
- Degree of protection IP65. - 1 NC + 1 NO or 2 NC contacts. - Reset by pushbutton, mushroom head pushbutton with or without key release, pull knob. - Visual indication of contact status and trip wire tension (option). - Approvals: CE and UL/CSA Others rope pull switches XY2CB (up to 100 or 2 x 100 metre trip wires)
- Contact housing degree of protection IP65, enclosure IP22. - 1 NC + 1 NO or 2 NC contacts. - Reset by pull knob. - Visual indication of contact status (option).-Range Benefits:Safety with complete freedom with emergency stops rope pull switchesA range of safety products which are simple to use and set up, with compact and ergonomic products to meet the requirements for performing emergency stops on dangerous machines.-Range Application Presentation:Emergency stop rope pull switches for all machines requiring stopping of dangerous movement in the immediate vicinity of the machine
Rope pull switches for all machines requiring stopping of movement in the immediate vicinity of the machine
GBP
Stock Code: XY2CJL17
Call for availability on 0345 030 60 80
165.07£137.56 (exc VAT) per 1
£165.07 (inc VAT)
Quantity: - +
e-stop rope pull switch XY2CJ - left side - 2NC - Pg13.5.Label:Preventa XY2C-range of product:Preventa XY2-product or component type:latching emergency stop rope pull switch-device short name:XY2C-Range Presentation:Robust metal enclosure for use in severe environments Emergency stops rope pull switches conforming to EN/ISO 13850, EN/IEC 60947-5-5
XY2CH (up to 15 metre trip wire)
- Reversible for trip wire anchoring point on the left or right - Degree of protection IP65. - 1 NC + 1 NO or 2 NC contacts - Reset by pushbutton, mushroom head pushbutton with or without key release, pull knob. - Visual indication of contact status and trip wire tension. - Approvals: CE and UL/CSA XY2CE (up to 50 metre trip wire)
- Degree of protection IP65. - 1 NC + 1 NO or 2 NC contacts. - Reset by pushbutton, mushroom head pushbutton with or without key release, pull knob. - Visual indication of contact status and trip wire tension (option). - Approvals: CE and UL/CSA Others rope pull switches XY2CB (up to 100 or 2 x 100 metre trip wires)
- Contact housing degree of protection IP65, enclosure IP22. - 1 NC + 1 NO or 2 NC contacts. - Reset by pull knob. - Visual indication of contact status (option).-Range Benefits:Safety with complete freedom with emergency stops rope pull switchesA range of safety products which are simple to use and set up, with compact and ergonomic products to meet the requirements for performing emergency stops on dangerous machines.-Range Application Presentation:Emergency stop rope pull switches for all machines requiring stopping of dangerous movement in the immediate vicinity of the machine
Rope pull switches for all machines requiring stopping of movement in the immediate vicinity of the machine

No detailed specifications are available for this product.